Using the Interface Assistant

Sometimes the imported network data does not have all the information that import needs to fully configure the device models. When this happens, you can supply the missing information after the import. The missing information that can be specified in the Interface Assistant falls into the following categories:

  • Unconnected Unnumbered Interfaces – Because the interface does not have an IP address, import cannot infer connectivity and requires user input to properly connect
  • Unspecified Data Rates – Import connects two interfaces or ports but cannot determine the data rate of the connection due to lack of operational or configuration data containing this information

This section describes the use of the Interface Assistant dialog box and contains the following:

Table 7: Interface Assistant Actions

Action Description
Opening the Interface Assistant Describes how to open the Interface Assistant
Interface Assistant Preference Set the preference to specify when the Interface Assistant should appear
Connect Unconnected Unnumbered Interfaces Establish connections between unconnected unnumbered interfaces and apply to network model
Specify Data Rates on Interfaces Establish the correct data rate on interfaces with unspecified data rates.
Push Changes from Interface Assistant to NetCollector Send the changes you made back to the NetCollector so that future imports will have the correct information for the interfaces
Save Interface Assistant Changes to Model Assistant File Save the changes to a model assistant (.ma) file, which you can apply during future imports. Doing so negates the need to correct the interfaces through the Interface Assistant in future imports.

Opening the Interface Assistant

The Interface Assistant appears when more information is needed during import, depending on the preference setting (see also Interface Assistant Preference). Alternatively, you can open the Interface Assistant by choosing Topology > Open Interface Assistant....

Interface Assistant Preference

The preference “Display interface assistant” specifies when the Interface Assistant will appear during import. The following three settings are available:

  • Only if required – (Recommended) The dialog box to appear only when changes or corrections are needed.
  • Always – The dialog box will appear even when no corrections are needed.
  • Never – The dialog box will not appear, even when you have missing information; however, you can still access the dialog box through the menu option Topology > Open Interface Assistant....

The following figure shows the Interface Assistant.

Figure 13: Interface Assistant

Interface Assistant

Connect Unconnected Unnumbered Interfaces

When unconnected, unnumbered interfaces are detected in the network model, the Interface Assistant opens with the Unconnected Unnumbered tab up front. You can use the Interface Assistant to connect these interfaces using the following procedure.

WARNING: This procedure applies only to interface connections that were missing in the configuration data; you cannot use this method to change connections that were set during the import (which appear with dark green icons when expanded in the Interface Assistant).

Procedure 1: Connect Unconnected Unnumbered Interfaces

  1. Select the Unconnected Unnumbered Interfaces tab, if it is not already selected.

    Result: All routers with unnumbered, unconnected interfaces appear in the left pane.

  2. Expand the devices by clicking on the plus sign (Windows) or arrow (Linux) next to the router icon.

    Figure 14: Interface Assistant—Unconnected Unnumbered Interfaces

    Interface Assistant—Unconnected Unnumbered Interfaces

  3. Select the interface of one end of the connection you want to make in the left pane.

    Result: Available interfaces to which you can connect appear in the right pane.

  4. Select the interface in the right pane to which you want to connect, and click the Connect button.

    Result: The two interfaces are connected. The new connections appear in the Connections Created pane at the bottom of the dialog box and are colored green. If you want to disconnect the interfaces, select the connection and click on the Disconnect button. When you have connected all interfaces, all of the formerly red icons will be light green, indicating that the interface has been modified and is now properly connected.

    Figure 15: Interface Assistant—Connections Created

    Interface Assistant—Connections Created

Specify Data Rates on Interfaces

With the Interface Assistant, you can set the data rate on interfaces for which no specified data rate was found during import. When you set a data rate, the change affects the interfaces on either end of the connection because dissimilar interfaces cannot transmit and receive data. You can also push the new data rate specifications to the NetCollector from which you imported the network model or you can save the changes to a Model Assistant file.

Note: The data rate of any links connecting these interfaces is set appropriately when you apply the new data rate.

Procedure 2: Specify the Data Rate of an Interface

  1. Select the Unspecified Data Rate tab in the Interface Assistant, if it is not already selected.

    Result: A list of routers with unspecified data rates appears.

    Figure 16: Interface Assistant—Unspecified Data Rates

    Interface Assistant—Unspecified Data Rates

  2. Expand the list of interfaces for each router by clicking on the plus sign next to the router.

    Result: Interfaces with unspecified data rates appear red.

  3. Select the interface whose data rate you want to change. You can select multiple interfaces by holding down the Control key and clicking on multiple interfaces. The data rate indicated for an interface is the default data rate that will be assigned if you do not specify the actual data rate.

    Figure 17: Interface Assistant—Set Data Rate

    Interface Assistant—Set Data Rate

  4. Choose a data rate from the Set pull-down menu. If the rate you want does not appear on this menu, choose “Edit...” and specify the data rate (in bps). Then click Apply.

    Result: The Data Rate fields for both interfaces are updated to reflect the change, and the displayed interface now has a green icon. The displayed data rate now shows the data rate you applied.

    Figure 18: Interface Assistant—New Data Rate Set

    Interface Assistant—New Data Rate Set

Push Changes from Interface Assistant to NetCollector

You can push the changes you made in the Interface Assistant to the NetCollector so that interface information will be complete during subsequent imports. To do this, click the Save to NetCollector button, as shown in the figure below.

Figure 19: Push Changes from Interface Assistant to NetCollector

Push Changes from Interface Assistant to NetCollector

You are prompted for the NetCollector name. Enter or confirm the name given, and click OK to push the changes to the server and continue.

Changes are applied to the network model when you click OK in the Interface Assistant.

Save Interface Assistant Changes to Model Assistant File

You can save the changes you made in the Interface Assistant to a model assistant file, which you can then use during another import. To create a model assistant file from the changes made in the Interface Assistant, click the Save As... button after you have specified all of the missing information. Provide a name for the model assistant file you want to create in the primary models directory.

Figure 20: Save Changes from Interface Assistant to a Model Assistant File

Save Changes from Interface Assistant to a Model Assistant File

Enter a filename, and click OK to save the .ma file and continue. Changes are applied to the network model when you click OK in the Interface Assistant.