intstop

Abstract

Sets a breakpoint for the specified module and interrupt type. The breakpoint will stop the simulation when the specified type of interrupt occurs at the specified module.

Syntax

intstop <objref> <intrpt>

intstop <objref> statwire [<statwire_index>]

intstop <objref> stream [<stream_index> [<packet_id>] ]

intstop <objref> self|process|remote [<intrpt_code>]

Argument Type Description
<objref> integer or string numeric object ID or hierarchical name of the module-of-interest
An object ID for this argument can be obtained by using the ODB commands objmap or objid.
<intrpt> string type of the interrupt to trap
The list of interrupt type keywords appears below in Details.
<statwire_index> int [optional] Sets the breakpoint for any interrupt from the specified statistic wire. (valid only for statwire interrupts)
<stream_index> int [optional] Sets the breakpoint for any packet arriving on the specified stream. (valid only for stream interrupts)
<packet_id> int [optional] Sets the breakpoint for a specific packet arriving on the stream specified by <stream_index>. (valid only for stream interrupts when a stream index has been specified)
<intrpt_code> int [optional] Sets the breakpoint for interrupts with the specified code. (valid only for self, process, and remote interrupts)

Details

An interrupt breakpoint is trapped when an event that would cause the specified interrupt at the specified module is removed from the event list immediately prior to its execution. Interrupt breakpoints are indefinite since they are associated with a repeatable situation, and they remain on the pending breakpoint list after being trapped. Breakpoints can be suspended by suspstop, reactivated by actstop, or deleted by delstop.

Valid <intrpt> arguments:

  • access
  • begsim
  • endsim
  • failure
  • interface
  • multicast
  • procedure
  • process
  • recovery
  • regular
  • remote
  • self
  • statwire
  • stream

Example

ODB> intstop pksw2.node0.proc stream
Added breakpoint # 0: stop at (stream intrpt) for module (top.pksw2.node0.proc) [Objid=42]

ODB> status

Breakpoints :
      0  stop at (stream intrpt) for module (top.pksw2.node0.proc) [Objid=42]


Traces :
      Full trace is disabled
      Encapsulation trace is enabled
      Execution trace is disabled
      Trace format: indented

      No other traces


Actions :
      None


Miscellaneous :
      Memory tagging is disabled


ODB> cont

__________________________ (ODB 18.6.0: Event) ____________________________

    * Time   : 3.06043019021 sec, [3s . 60ms 430us 190ns 214ps]
    * Event  : execution ID (60), schedule ID (#70), type (stream intrpt)
    * Source : execution ID (59), top.pksw2.node0.src (processor)
    * Data   : instrm (1), packet ID (16)
    > Module : top.pksw2.node0.proc [Objid=42] (processor) [process id: 173]

breakpoint #0 trapped: "stop at (stream intrpt) for module (top.pksw2.node0.proc [Objid=42])"