Esys Modules

Figure 161: Standard Icon Used for an esys Module

Standard icon for an esys module

The external system module, or esys module, provides a superset of the queue’s functionality. In addition to all of the attributes that a queue has, an esys module also has an “esd model” attribute, which specifies an external system definition (ESD) model to use during a cosimulation. If “esd model” is set to NONE (the default), the esys module behaves exactly like a queue.

Double-clicking on an esys module opens the Process Editor, in which you can edit the esys module’s process model. To create or edit the esys module’s ESD, click the Edit ESD Model button in the esys module’s Attributes dialog box. When an esys module uses an ESD model, the module’s process model acts as the interface between the external system and the rest of Modeler. Therefore, the process model is Modeler’s interface to the external system.