Network Object Attribute Descriptions

altitude modeling

This attribute determines how the Simulation Kernel interprets an object altitude attribute. Three settings are possible

  • relative to subnet–The altitude setting is interpreted as the object altitude above the current subnet.
  • absolute–The altitude setting is the object altitude above global sea level.
  • relative to terrain–The altitude setting is the object altitude above the underlying terrain (mountain, valley, ocean, etc.)

This attribute appears only if the Wireless module is in use.

Editing Simulation
Data Type enumerated enumerated
Access read/write/promote read
Default Value relative to subnet
Units
Constraints see description

Application Configuration

This attribute sets the traffic characteristics for the different applications to be supported on this client.

Editing Simulation
Data Type compound compound
Access read/write read/write
Default Value Off
Units
Constraints

arrowheads

This attribute specifies whether arrowheads appear at the ends of the object when depicted in the Project Editor.

Editing Simulation
Data Type enumerated string
Access read/write read
Default Values simplex point-to-point link: “tail”
duplex point-to-point link: “head and tail”
bus tap: “head and tail”
path: “head and tail”
demand: “tail”
Units
Constraints head and tail, head, tail, none

attribute promotion

This attribute allows you to control the display of promoted attributes. When enabled, promoted attributes of objects contained in the subnet appear in the subnet attribute list. When disabled, promoted attributes do not appear in the list, nor do they promote to the parents of the subnet.

The attribute is most useful when a model contains many levels of nested subnets, each with many nodes and many promoted attributes. In this case, displaying the Attributes dialog box of any subnet (especially the top subnet), or scrolling through the list of attributes, can be slow and cumbersome. It is recommended that you set “attribute promotion” to disabled except when you need to display or modify the value of a promoted attribute on a subnet.

Although promoted attributes do not appear in the subnet attribute list when the attribute value is “disabled”, they still must be resolved at simulation run time.

Editing Simulation
Data Type toggle not applicable
Access read/write not applicable
Default Value disabled
Units
Constraints

ber

This attribute can be used to specify the probability of bit errors in packets that are transmitted over a link. Typically, the ber is translated into bit errors by the error model of the link’s pipeline. For example, with a ber of 0.1, packets with a length of 100 bits will average 10 bit errors.

If this attribute is set to NONE, the pipeline stage is skipped and the Simulation Kernel uses a default value, as described in “Pipeline Stage Definition” on page 356.

See Chapter 9 “Communication Mechanisms” on page 331 for details on the transceiver pipeline.

Editing Simulation
Data Type double double
Access read/write/promote read/write
Default Value 0.0
Units errors/bit
Constraints 0.0 <= ber <= 1.0

bundle display

This attribute sets the link bundling option for the specified link. When “network_visualization.auto_link_bundling” preference is activated, set the “bundle display” attribute to override the preference.

The “bundle display” attribute settings are

  • include in bundle and display fanned out – Specifies to include the link in a bundle. Additionally, by default, display the link in an expanded bundle.
  • include in bundle and display collapsed – Specified to include the link in a bundle. Additionally, by default, display the link in a collapsed bundle.
  • exclude from bundle – Specifies to exclude the link from any bundle.
Editing Simulation
Data Type enumerated not applicable
Access read/write not applicable
Default Value include in bundle and display collapsed
Units
Constraints include in bundle and displayed fanned out, include in bundle and display collapsed, exclude from bundle.

channel count

This attribute specifies the number of channels in the link. To achieve link consistency, this must be the same number of channels supported by the transmitters and receivers of nodes attached to the link.

Editing Simulation
Data Type integer integer
Access read/write read
Default Value 1
Units
Constraints >= 1

For more information about link consistency, see Chapter 7 “Network Domain” on page 292.

closure model

This attribute specifies the name of a compiled pipeline procedure capable of determining the connectivity between any transmitter and receiver on the bus. The purpose of this stage is to allow the user to impose restrictions on which transmitter-receiver pairs can communicate. The default assignment for this pipeline stage is the base model dbu_closure which allows closure between all transmitters and receivers.

If this attribute is set to NONE, the pipeline stage is skipped and the Simulation Kernel uses a default value, as described in “Pipeline Stage Definition” on page 356.

Editing Simulation
Data Type typed file string
Access read/write read
Default Values dbu_closure
Units
Constraints

For more information about dbu_closure, see Chapter 3 “Pipeline Stages/Bus Link” on page 6.

coll model

This attribute specifies the name of a compiled pipeline procedure which is invoked to register that a collision has occurred when two packets are simultaneously present at the same receiver channel on the bus link. The number of collisions a packet experiences is typically recorded in the packet transmission data. Typically, this information is then used by the “error correction” pipeline stage to determine whether to accept or reject a packet at a receiver channel. The default assignment for this pipeline stage is the base model dbu_coll which considers any packets that overlap in time at a bus receiver channel to be collided.

If this attribute is set to NONE, the pipeline stage is skipped and the Simulation Kernel uses a default value, as described in “Pipeline Stage Definition” on page 356.

For a detailed description of dbu_coll, see Chapter 3 “Pipeline Stages/Bus Link” on page 6.

Editing Simulation
Data Type typed file string
Access read/write read
Default Value dbu_coll
Units
Constraints

color

This attribute specifies the color of an instance of the object when displayed in the Project Editor. This attribute has no effect on simulation. Clicking in the Value column for this attribute opens the Color Chooser.

“color” can have values ranging from RGB000 to RGB333, where each digit is an integer between 0 and 3 inclusive. The higher the first digit, the more red, the higher the second digit, the more green, and the higher the third digit, the more blue. Thus, RGB000 corresponds to black, RGB333 corresponds to white, RGB300 corresponds to red, and so on.

Editing Simulation
Data Type color not applicable
Access read/write not applicable
Default Values point-to-point link: RGB000
bus link: RGB023
bus tap: RGB222
path: RGB003
demand: RGB010
Units
Constraints

condition

This attribute represents the operational status of the object. A value of “enabled” signifies that the object is active and can perform all usual functions of that object type. A value of “disabled” signifies that the object is unable to perform any functions. For example, disabled links cannot forward packets and attempted transmissions are dropped.

Users interested in the effects of a node becoming disabled can modify the “condition” attribute during simulation using the KP op_ima_obj_attr_set(). Changing the value from “enabled” to “disabled” creates failure interrupts at selected modules. Changing the value from “disabled” to “enabled” creates recovery interrupts at selected modules.

Editing Simulation
Data Type toggle toggle
Access read/write/promote read/write
Default Value enabled
Units
Constraints enabled, disabled

For more information about modeling failures and recoveries, see “Modeling Node and Link Failure/Recovery” on page 313.

cost

This attribute is a double-precision floating-point number that is primarily intended as a routing parameter. This parameter typically is used by routing APIs that determine the total cost of a route. This value can also be used explicitly by the user in developing a new routing algorithm.

Editing Simulation
Data Type double double
Access read/write/promote read/write
Default Value 0.0
Units
Constraints cost >= 0.0

creation data

This attribute specifies additional information about the creation of the object.

Editing Simulation
Data Type string not applicable
Access read/write not applicable
Default Value “”
Units
Constraints

creation source

This attribute specifies how the object was created.

Editing Simulation
Data Type string not applicable
Access read/write not applicable
Default Value “Object Palette”
Units
Constraints

creation timestamp

This attribute specifies when the object was created.

Editing Simulation
Data Type date not applicable
Access read/write not applicable
Default Value
Units
Constraints

data rate

This attribute specifies the speed of data transmission over the link. This speed applies only to the first channel supported by the link and must match the data rate of channel [0] of the transmitters and receivers in attached nodes. A special value of “unspecified” allows the link to obtain its data rate at simulation run time from the transmitter and receiver channels in attached nodes.

Editing Simulation
Data Type double double
Access read/write/promote read/write
Default Value 1024.0
Units bits/second
Constraints data rate > 0.0

delay

For point-to-point links, this attribute usually specifies an absolute propagation delay, in seconds, that will be experienced by packets sent over the link. This value is used by the propagation delay stage of the pipeline. Typically, the value assigned to “delay” is the total propagation delay across the link, or zero if the effects of propagation delay are considered negligible. If this attribute has the symbolic value “Distance Based”, the propagation delay is determined based on the distance from source to destination and the propagation speed.

For bus links, this attribute is a positive double-precision floating-point number typically used in computing the propagation delay that will be incurred by packets sent over the bus. This value is specified in units of “seconds per meter” and represents the simulated time required for a signal to propagate one meter of distance within the bus. This value is used in the propagation delay (propdel) stage of the bus pipeline. Distance is measured along the path of the bus link as specified by the user, as opposed to a simple distance calculation between the communicating transceivers. The default value of 0.0 implies that all receivers attached to the bus receive transmissions at the same simulation time.

Editing Simulation
Data Type double double
Access read/write/promote read/write
Default Value 0.0
Units point-to-point link: seconds
bus link: seconds/meter
Constraints delay >= 0.0

ecc model

This attribute specifies the name of a compiled pipeline procedure that determines whether or not a packet transmitted over a link can be accepted by the receiver in a destination node. The pipeline procedure can use any application-specific criteria in determining whether a packet is accepted or rejected. However, in general, this decision is based on the quantity of erroneous bits present in the packet.

  • For point-to-point links, the default model simply compares the proportion of bit errors present with the value of the ecc threshold attribute for the receiver. If the number of errors exceeds the threshold, the packet is rejected.
  • For bus links, the default model first checks if the packet experienced any collisions. If it did, the packet is rejected by the receiver channel. If the packet did not experience any collisions, the default model next checks the number of bit errors in the packet. If the number of errors in the packet exceeds the value of the ecc threshold attribute for the bus receiver, it rejects the packet. If the packet has experienced no collisions and has fewer errors than the ecc threshold, it is accepted by the receiver.

If this attribute is set to NONE, the pipeline stage is skipped and the Simulation Kernel uses a default value, as described in “Pipeline Stage Definition” on page 356.

See Chapter 9 “Communication Mechanisms” on page 331 for information about the transceiver pipeline.

Editing Simulation
Data Type typed file string
Access read/write read
Default Value point-to-point link: dpt_ecc
bus link: dbu_ecc
Units
Constraints

error model

This attribute specifies the name of a compiled pipeline procedure that calculates the number of bit errors in a given packet transmitted over a link. The number of bit errors must be an integer greater than or equal to zero and less than or equal to the number of bits contained in the packet. The default model calculates a total number of bit errors for a packet based on the value of the ber attribute and the length of the packet.

If this attribute is set to NONE, the pipeline stage is skipped and the Simulation Kernel uses a default value, as described in “Pipeline Stage Definition” on page 356.

See Chapter 9 “Communication Mechanisms” on page 331 for more information about the transceiver pipeline.

Editing Simulation
Data Type typed file string
Access read/write read
Default Value point-to-point link: dpt_error
bus link: dbu_error
Units
Constraints

financial cost

This attribute specifies the cost of purchasing or maintaining the object.

Editing Simulation
Data Type string string
Access read/write/promote read/write
Default Value “0.00”
Units
Constraints

hostname

Editing Simulation
Data Type string not applicable
Access read/write/promote not applicable
Default Value “”
Units
Constraints

icon name

This attribute specifies the bitmap used to represent the object in network diagrams. Icons can be created with the Icon Editor. The value of this attribute has no impact on simulation behavior.

Editing Simulation
Data Type icon not applicable
Access read/write not applicable
Default Values subnetwork: subnet
fixed communications node: fixed_comm
Units
Constraints

IP Address Information

Allows the configuration of the following:

  • Number of IP interfaces
  • IP address for each interface
  • Subnet mask for each interface
  • MTU for each IP interface

A value of No IP Interfaces means that no IP interfaces have been set up.

Editing Simulation
Data Type compound compound
Access read/write read/write
Default Value No IP Interface
Units
Constraints

IP Forwarding Rate

Number of packets that are processed by the central processor in one second. The service rates for slot processors are specified in the IP Slot Information attribute.

Editing Simulation
Data Type double double
Access read/write read/write
Default Value 5000.0
Units packets/second
Constraints

IP Processing Scheme

Controls the number of servers (processors) and queues used by IP for packet forwarding. In central processing, one server with one queue is used to process all packets. In slot based processing, in addition to one central server (with its own queue), additional servers, each with its own queue, are used to process packets. The number of additional servers is determined by the number of slots that have been configured. The IP Slot Information model attribute controls the number of slots used by an IP process instance. When used with multiple servers, slot based processing can deliver greater packet throughput.

Editing Simulation
Data Type integer integer
Access read/write read/write
Default Value Central Processing
Units
Constraints

IP Slot Information

Typically, IP routing devices have slots, each with its own slot processor. This attribute allows the modeling of such slotted devices in association with the IP model. The information in this attribute is used only when the Router Processing Scheme attribute is set to Slot Based Processing. The value NOT USED represents zero slots.

Editing Simulation
Data Type compound compound
Access read/write read/write
Default Value
Units
Constraints

label color

Specifies the label color of the corresponding node. You can set the attribute for each node (and subnet) to contrast with the background. The default color is black.

Editing Simulation
Data Type color not applicable
Access read/write not applicable
Default Value black
Units
Constraints

label rotation

Specifies the rotation of link labels. By default, link labels are displayed horizontally. However, you can rotate the label using the link attribute “label rotation”. The “label rotation” attribute can be set to horizontal, vertical, parallel to link, or perpendicular to link.

Editing Simulation
Data Type enumerated not applicable
Access read/write not applicable
Default Value horizontal
Units
Constraints

LAN Background Utilization

Provides a method for creating a baseline load on this object. This load, called background utilization, is specified as a percentage of the data rate. Different values can be specified for different simulation-time duration. Traffic specified by this attribute does not include imported traffic, nor does it include traffic generated explicitly by network sources. Background utilization traffic is included in the total traffic load when calculating statistics.

Editing Simulation
Data Type compound compound
Access read/write read/write
Default Value
Units
Constraints

LAN MAC Address

Address of the Ethernet MAC representing this LAN.

Editing Simulation
Data Type integer integer
Access read/write read/write
Default Value auto-assigned
Units
Constraints

LAN Server Name

Name of the server residing in the LAN. Clients from other LANs can communicate to the server in the LAN by specifying this name as their Server Name.

Editing Simulation
Data Type string string
Access read/write read/write
Default Value auto-assigned
Units
Constraints

LAN Type

Type of Ethernet LAN. Valid LAN types are as follows:

  • Ethernet: 10BaseT
  • Fast Ethernet: 100BaseT
  • Gigabit Ethernet: 1000BaseX
  • FDDI: 100Mbps
  • Token Ring 4: 4Mbps
  • Token Ring 16: 16Mpbs
Editing Simulation
Data Type integer integer
Access read/write read/write
Default Value Ethernet
Units
Constraints

line style

This attribute allows you to modify the line style that represents the link within network diagrams. It has no effect on simulation behavior.

Note: You can only set the “line style” attribute on individual instances of link objects. It does not appear in the link model interfaces, so you cannot set this attribute for link objects on a model-wide basis.

Editing Simulation
Data Type enumerated not applicable
Access read/write not applicable
Default Values link: solid
path: solid
demand: dotted
Units
Constraints solid, dashed, dotted

map

This attribute specifies the name of a cartographic data set file with a “.cds” suffix (the suffix is not included in the attribute value) whose content is depicted in the Project Editor.

This attribute has no effect on simulations.

Editing Simulation
Data Type typed file not applicable
Access read/write not applicable
Default Value
Units
Constraints

minimized icon

This attribute specifies how the subnet will be displayed when scaling would cause it to appear too small to be represented by its original icon.

Editing Simulation
Data Type minimized icon not applicable
Access read/write not applicable
Default Value subnetwork: “circle/#FF0000”
communication node: “circle/#708090”
Units
Constraints

model

This attribute specifies the model on which the object is based. The primary role of the model is to specify how the object’s attributes are configured. The model represents the internal structure and therefore the capabilities of the object and can also cause the object to inherit attributes that have been promoted upwards.

See Chapter 6 “Node Domain” on page 263 to learn more about node models. See Chapter 9 “Communication Mechanisms” on page 331 for more information about link models.

Editing Simulation
Data Type enumerated string
Access read/write read
Default Value
Units
Constraints valid model name

name

This attribute specifies a string that is used for identification purposes. It is useful for identifying a link in a model report. It is also used during simulation to obtain the link object ID via the KP op_id_from_name(). The object ID is useful for getting attribute values and can also be used for routing or disabling/enabling links dynamically. The Riverbed Simulation Kernel makes no use of this attribute.

Editing Simulation
Data Type string string
Access read/write read
Default Values subnetwork: “subnet_n”, n >= 0
communication node: “node_n”, n >= 0
simplex point-to-point link: “<src_node> -> <dest_node>”
duplex point-to-point link: “<src_node> <-> <dest_node>”
bus link: “bus_n”, n >= 0
bus tap: “<bus> - <node>”
path: “<src_node> <-> <dest_node>”
demand: “<src_node> <-> <dest_node>”
Units
Constraints unique name, no dots, not “top”

Number of Workstations

Total number of workstations in a given LAN. Each LAN is composed of a number of workstations and a built-in server.

Editing Simulation
Data Type integer integer
Access read/write read/write
Default Value 10
Units
Constraints

outline color

This attribute specifies the color of a subnetwork perimeter display for the purpose of its depiction in the Project Editor. This attribute has no effect on simulation. Clicking in the Value column for this attribute opens the Color Chooser.

“outline color” can have values ranging from RGB000 to RGB333, where each digit is an integer between 0 and 3, inclusive. The higher the first digit, the more red, the higher the second digit, the more green, and the higher the third digit, the more blue. Therefore, RGB000 corresponds to black, RGB333 corresponds to white, RGB300 corresponds to red, and so on.

Editing Simulation
Data Type color not applicable
Access read/write not applicable
Default Value RGB133
Units
Constraints

packet formats

This attribute specifies which packet formats are supported by the link. These formats must match the ones being used by the transmitters and receivers in attached nodes; if not, the link will not be operational during simulation. The Project Editor makes use of this attribute as part of a link consistency determination. Link consistency analyzes the compatibility of nodes and links that are connected to each other. See Chapter 7 “Network Domain” on page 292 for more information about link consistency.

Editing Simulation
Data Type string string
Access read/write read
Default Value “all formatted,unformatted”
Units
Constraints

priority

This attribute is used when multiple events are scheduled for the same simulation time, to determine in which order they will be executed. Higher priority events are executed first. Event priority is evaluated hierarchically with subnet priority being weighted higher than node priority, which in turn is weighted higher than module priority. Only the priority of the lowest parent subnet is considered when evaluating the priority of an event occurring at a module.

This attribute is not used by the parallel simulation kernel.

Editing Simulation
Data Type integer integer
Access read/write/promote read/write
Default Value 0
Units
Constraints Abs value(priority) <= 32,000

propdel model

This attribute specifies the name of a compiled pipeline procedure that calculates propagation delay between a transmitter and a receiver communicating via a link. The propagation delay is the simulated time separating the transmission of the first bit of the packet from the reception of the first bit of the same packet.

  • For point-to-point links, the default model simply sets the propagation delay equal to the value of the link’s “delay” attribute.
  • For bus links, the default model calculates a delay time based on the distance separating the bus transmitter and receiver of interest and the value of the “delay” attribute of the bus link.

If this attribute is set to NONE, the pipeline stage is skipped and the Simulation Kernel uses a default value, as described in “Pipeline Stage Definition” on page 356.

See Chapter 9 “Communication Mechanisms” on page 331 for more information about the transceiver pipeline.

Editing Simulation
Data Type typed file string
Access read/write read
Default Value point-to-point link: dpt_propdel
bus link: dbu_propdel
Units
Constraints

receiver

This attribute specifies a bus receiver in an attached node as the destination for packets arriving over the attached bus. If the value of this attribute is set to NONE or left empty, then this node will not receive packets via this tap. In this case, the tap will graphically appear as a unidirectional tap from the node to the bus link (a transmit only tap).

The value of this attribute is specified as the name of the node, followed by a dot (.) separator, and followed by the name of the bus receiver. An example receiver value is node_0.br_0 where the node is named node_0 and the bus receiver is named br_0.

Editing Simulation
Data Type enumerated string
Access read/write read
Default Value
Units
Constraints

receiver a

This attribute designates which point-to-point receiver within the first attached node receives packets from the duplex point-to-point link. The attribute value must correspond to the name of a point-to-point receiver within the node model for the link to be operational. The value of this attribute is specified as the name of the node, followed by a dot (.) separator, followed by the name of the point-to-point receiver. For example, a valid value is node_0.pr_0, where the node is named node_0 and the receiver is named pr_0.

Editing Simulation
Data Type enumerated string
Access read/write read
Default Value
Units
Constraints

receiver b

This attribute designates which point-to-point receiver within the second attached node receives packets from the duplex point-to-point link. The attribute value must correspond to the name of a point-to-point receiver within the node model for the link to be operational. The value of this attribute is specified as the name of the node, followed by a dot (.) separator, followed by the name of the point-to-point receiver. For example, a valid value is node_0.pr_0, where the node is named node_0 and the receiver is named pr_0.

Editing Simulation
Data Type enumerated string
Access read/write read
Default Value
Units
Constraints

right-angled

This attribute specifies the right-angled property, which is used to draw simplex and duplex point-to-point links. This attribute has no effect on the simulation.

Editing Simulation
Data Type toggle not applicable
Access read/write not applicable
Default Value disabled
Units
Constraints disabled, enabled

role

This attribute describes the purpose served by the object.

Editing Simulation
Data Type string not applicable
Access read/write/promote not applicable
Default Value “”
Units
Constraints

Server Background Utilization

Specifies mean baseline loads for this server. Delays representing the effects of the background load are calculated for each explicitly-modeled job being serviced.

Each entry in this table has a start time and a background utilization. The utilization applies until the start time of the next entry (or to the end of simulation in the case of the last entry).

Editing Simulation
Data Type compound compound
Access read/write read/write
Default Value
Units
Constraints

Server Configuration

Defines application services supported at this server. Also allows server parameter configuration for each client application.

Editing Simulation
Data Type compound compound
Access read/write read/write
Default Value
Units
Constraints

Server Processing Speed Multiplier

The number of job units the server processes in one second. The server uses this value to compute the request response rate.

Editing Simulation
Data Type double double
Access read/write read/write
Default Value 1.0
Units
Constraints

Start Time

The start time for each application supported by the node.

Editing Simulation
Data Type compound compound
Access read/write read/write
Default Value 100
Units Seconds
Constraints

Stop Time

The stop time for each application supported by the node.

Editing Simulation
Data Type compound compound
Access read/write read/write
Default Value End of Simulation
Units
Constraints

Switching Speed

Specifies the rate at which packets are switched from the switch processor to the appropriate output port. Typically, this is the speed of the switch used in a LAN.

Editing Simulation
Data Type double double
Access read/write read/write
Default Value 500 000
Units packets per second
Constraints

symbol

This attribute specifies a graphical symbol that appears over the midpoint of each segment of the object. It has no effect on simulation behavior.

Editing Simulation
Data Type enumerated not applicable
Access read/write not applicable
Default Value “none”
Units
Constraints none, circle, square, triangle, diamond

TCP Maximum Segment Size

Maximum Segment Size (MSS) that the underlying network can carry without fragmenting. Used to determine the size of segments sent by TCP.

Editing Simulation
Data Type integer integer
Access read/write read/write
Default Value 536
Units bytes
Constraints

thickness

This attribute specifies the thickness (in pixels) of the line used to draw the object. It has no effect on simulation behavior.

Editing Simulation
Data Type integer integer
Access read/write read
Default Values point-to-point link: 1
bus link: 5
bus tap: 1
path: 5
demand: 1
Units
Constraints

threshold

This attribute affects the object’s display characteristics at different zoom levels. If its value is higher than the current resolution of the map, the object will be displayed as a miniaturized icon. Typically, this attribute is used to ensure that network diagrams do not become cluttered with icons at higher zoom levels. The current resolution of the map can be determined in the Project Editor from the dialog box that appears in response to the View > Background > Set Properties command. In the top subnet level, this attribute is measured in pixels/degree and in all other subnet levels, it is measured in pixels/unit of the subnet.

Editing Simulation
Data Type double not applicable
Access read/write not applicable
Default Value 0.0
Units see description
Constraints

transmitter

This attribute designates which transmitter in the attached node acts as a source for packets to be put onto the link. The value of this attribute is specified as the name of the node, followed by a dot (.) separator, followed by the name of the bus transmitter. For example, a valid value is node_0.pt_0, where the node is named node_0 and the transmitter is named pt_0.

For bus taps, if the value of this attribute is set to NONE or left empty, the node will not transmit packets via this tap. In this case, the link will graphically appear as a unidirectional tap from the bus link to the node (a “receive only” tap).

Editing Simulation
Data Type enumerated string
Access read/write read
Default Value
Units
Constraints must be unique

transmitter a

This attribute designates which point-to-point transmitter in the first attached node acts as a source for the duplex point-to-point link. The attribute value must correspond to the name of a point-to-point transmitter within the node model for the link to be operational. The value of this attribute is specified as the name of the node, followed by a dot (.) separator, followed by the name of the point-to-point transmitter. For example, a valid value is node_0.pt_0, where the node is named node_0 and the transmitter is named pt_0.

Editing Simulation
Data Type enumerated string
Access read/write read
Default Value
Units
Constraints

transmitter b

This attribute designates which point-to-point transmitter in the second attached node acts as a source for the duplex point-to-point link. The attribute value must correspond to the name of a point-to-point transmitter within the node model for the link to be operational. The value of this attribute is specified as the name of the node, followed by a dot (.) separator, followed by the name of the point-to-point transmitter. For example, a valid value is node_0.pt_0, where the node is named node_0 and the transmitter is named pt_0.

Editing Simulation
Data Type enumerated string
Access read/write read
Default Value
Units
Constraints

Transport Protocol

The transport protocol for each application supported by the node.

Editing Simulation
Data Type compound compound
Access read/write read
Default Value Depends on application
Units
Constraints

txdel model

This attribute is the name of a compiled pipeline procedure that calculates transmission delay associated with the transmission of a packet over a link, The transmission delay is the simulated time separating the transmission of the first bit of the packet from the transmission of the last bit of the same packet. The default model computes transmission delay based on the channel data rate and the length of the packet.

If this attribute is set to NONE, the pipeline stage is skipped and the Simulation Kernel uses a default value, as described in “Pipeline Stage Definition” on page 356.

See Chapter 9 “Communication Mechanisms” on page 331 of Modeling Concepts for more information on the transceiver pipeline.

Editing Simulation
Data Type typed file string
Access read/write read
Default Value point-to-point link: dpt_txdel
bus link: dbu_txdel
Units
Constraints

unit

This attribute contains the units used by objects within the subnet. The value is one of the OpT_Ima_Obj_Position_Unit_Type values (see Table 68 “Object Position Unit Type Symbolic Constants” on page 19).

Editing Simulation
Data Type not applicable integer
Access not applicable read
Default Value
Units
Constraints

user id

This attribute is an integer that is provided for user-specific identification purposes. Unlike sys id, it does not necessarily have the property of uniqueness, but it is a read/write variable and you can assign it in any way desired.

Editing Simulation
Data Type integer integer
Access read/write/promote read/write
Default Value 0
Units
Constraints

x position

This attribute specifies the horizontal position of the object. Because these are fixed objects, the value at specification time is also the value throughout the simulation, and this value cannot be changed dynamically. This attribute is specified in the units of the parent subnetwork. When the unit is degrees, this corresponds to longitude. A positive value refers to degrees East longitude and a negative value refers to degrees West longitude.

For communications nodes, this attribute is one of three components specifying position: x position, y position, and altitude. This attribute represents the distance separating the node from the left edge of the enclosing subnet extent.

For subnetworks, this attribute specifies the x-coordinate of the center of the subnetwork extent (which is also the x-coordinate of the position at which the subnetwork icon is displayed in the Project Editor).

Editing Simulation
Data Type double double
Access read/write read
Default Value
Units see description
Constraints

y position

This attribute specifies the vertical position of the object. Because these are fixed objects, the value at specification time is also the value throughout the simulation, and this value cannot be changed dynamically. This attribute is specified in the units of the parent subnetwork. When the unit is degrees, this corresponds to latitude. A positive value refers to degrees North latitude and a negative value refers to degrees South latitude.

For communications nodes, this attribute is one of three components specifying position: x position, y position, and altitude. This attribute represents the distance separating the node from the top edge of the enclosing subnet extent.

For subnetworks, this attribute specifies the y-coordinate of the center of the subnetwork extent (which is also the y-coordinate of the position at which the subnetwork icon is displayed in the Project Editor).

Editing Simulation
Data Type double double
Access read/write read
Default Value
Units see description
Constraints

本站文档由 北京智网畅联科技有限公司 整理、翻译并提供 · Documentation compiled and provided by Beijing ZNetLink Technology Co., Ltd.

交流群 · QQ Group:OPNET/智网妙算网络仿真交流群(群号 486383494)

原文档 © 2017 Riverbed Technology · 本站为公益翻译,由 AI 辅助完成,请仔细甄别

Original documentation © 2017 Riverbed Technology. Community translation, AI-assisted. Contact: jiazequn@znetlink.com