Starting 3D Network Visualizer Applications

The typical sequence for using a 3D Network Visualizer application is to:

  1. Start the application.
  2. Load a terrain database.
  3. Connect to a simulation network.

Note: If you want to connect to an HLA simulation, you must have an RTI installed.

Note: Before you can start 3D Network Visualizer, the license manager must be running.

Starting 3D Network Visualizer on Windows

To start 3D Network Visualizer on WIndows:

Procedure 22: Starting 3D Network Visualizer from the Windows GUI

  1. If desired, specify options by adding them to a shell variable named OP_3DNV_VISUALIZER_EXTRA_ARGS. The options available for 3D Network Visualizer appear in Command-Line Options.
  2. On the Windows Start menu, choose Programs > OPNET 3D Network Visualizer <rel> > 3DNV Communications <rel>, where <rel> is the 3D Network Visualizer release number.
  3. On the Windows Start menu, choose Programs > OPNET 3D Network Visualizer <rel> > OPNET 3D Network Visualizer <rel> (<rti>, <bitness>), where <rel> is the 3DNV release number, <rti> is the RTI type you are using, and <bitness> is the bitness of your operating system.

Starting 3D Network Visualizer on the Windows Command Line

To start 3D Network Visualizer on the Windows command line:

Procedure 23: Starting 3D Network Visualizer from the Windows Command Line

  1. Change directory to .\bin (for a 32-bit OS) or .\bin64.

  2. Enter:

    op_3dnv_launcher_13
    

    or

    op_3dnv_launcher_1516
    

    depending on which RTI you want to use (DOD 1.3 or IEEE 1516).

    Command-Line Options describes the 3D Network Visualizer command-line options.

Command-Line Options

Table 30 lists 3D Network Visualizer’s command-line options.

To use these options, add the desired options to a shell variable named OP_3DNV_VISUALIZER_EXTRA_ARGS before starting 3D Network Visualizer. For example:

set OP_3DNV_VISUALIZER_EXTRA_ARGS = --fullscreen
op_3dnv_launcher.exe

Table 30: 3D Network Visualizer Command-line Options

Option Description
(-- | --ignore_rest) Ignore all command-line options after this one. This option is useful for disabling part of a command line in a script for test purposes so that you do not have to retype all of the command options at a later point.
--appDataDir directory Specifies the location of application data.
-B | --bindObservers "observer1, ..., observern, saved_views_file" If you load a scene that has multiple observers, this command assigns the views in the specified saved views file to the specified observers. The first saved view is assigned to the first observer, the second to the second observer, and so on. If the observers are not specified as arguments, only the first observer in the display configuration gets a view assigned to it. The entire string must be quoted. There are no spaces after commas. You would ordinarily also specify a display configuration that contains the observers with --dispSetting. You must specify a terrain database for this command to work. For more information about using this command-line option, please see “Attaching the Observer at Startup“ on page 251.
(-C | --autoConnect) {filename | connector_name} Automatically connect to the network using the specified connector.
--dataDir directory Specifies the location of the data directory (terrains and so on).
--dispSetting filename Specifies the display configuration to load.
--entDispSetting filename Specifies the entity display setting to load.
--envSetting filenam Specifies the environment configuration file to load.
(-E | --entTypeMap) filename Load the specified entity type mapping file. The file extension determines the type of mapping.
--fullScreen Start with the window in full screen mode.
(-F | --frameRate) rate If rate is 0, the frame rate is variable. Otherwise, specifies a fixed frame rate for rendering.
(-G | --locale) language Specifies the locale (for localization).
(-h | --help) Display command-line usage information.
(-l | --logFileName) filename Specifies the log file name.
(-L | --loadObservers filename1 filenamen Loads the saved observers in the specified files.
(-n | --notifyLevel) notify_level Specifies the notification level for application messages, where notify_level is a number from 0 through 4. The least verbose message level is 0, the highest is 4. The default is 2.
--noGui Start without the graphical user interface.
--observerMode mode Specifies the observer mode for each observer in the startup configuration, for example Observer 1, Stealth. If you specify an observer that does not exist, the mode is not set. Accepted multiple times.
--plugin filename Load the specified plug-in. Can be used multiple times.
--showConsole Display a console window.
(terrain_MTF_file | scene_MSF_file) Specifies a terrain (MTF) or scene (MSF) file to load.
--unplug filename Do not load the specified plug-in. Can be used multiple times.
--userDataDir directory Specifies the user data directory.
(-v | --version) Display version information and exit.
--vsync Start with vsynched windows.
-W | --withDisplayEngine port@netAddress; displayConfigFilename1 ... n Connect to a display engine running on another computer. For more information, please see “Loading Multiple Display Engine Configurations from the Command Line“ on page 186.

Shutting Down 3D Network Visualizer

To shut down 3D Network Visualizer, choose File > Exit.