oms_wp_phy_alert_measure_avg_db_get()
Abstract
Obtains the average of the measured values, in dB or dBm (depending upon the measurement type), for the measurement that triggered the notification alert. To obtain the average measured value in linear scale, use oms_wp_phy_alert_measure_avg_get().
Syntax
oms_wp_phy_alert_measure_avg_db_get (alert_handle)
| Argument | Type | Description |
|---|---|---|
alert_handle |
OmsT_WP_Phy_Alert_Handle |
Alert handle |
Return Type
double
Details
If the measurement’s window is zero, the returned value is the last instantaneous measurement, and not the average.