HLA-PM Attributes
All attributes in this table are simulation attributes.
Table 2: HLA-PM Attributes
| Attribute | Description | Type/Default Value |
|---|---|---|
| HLA Abort On Failure | Whether the simulation should be aborted when the HLA-PM encounters a failure in the HLA interface. | Boolean FALSE |
| HLA Callback Set | Used to restrict the set of callbacks sent to the HLA esys module. This minimizes the time spent packaging and delivering information that may not be used. Note: You cannot use the hexadecimal format for integer preferences. Convert the bit pattern to a base-10 integer value (e.g., 255 instead of 0xFF). |
Integer 511 |
| HLA Create Federation | Whether the HLA-PM should attempt to create the federation. | Boolean TRUE |
| HLA Create Init Synchronization Point | Whether the HLA-PM should create the initial synchronization point. | Boolean FALSE |
| HLA Destroy Federation | Whether the HLA-PM should attempt to destroy the federation after resigning from it. | Boolean TRUE |
| HLA Factory | Name of the function that creates the model Federate Ambassador. | String cosim_factory |
| HLA Fed File Name | Name of the .fed file used. The default is the name of the federation. | String None |
| HLA Federate Name | The name of the federate. | String None |
| HLA Federation Name | Name of the federation to create (if HLA Create Federation is enabled) and join. | String None |
| HLA Init Synchronization Point | Name of the initial synchronization point. | String None |
| HLA Inter-event Tick | Specifies whether a tick() call should happen between every two consecutive events. When TRUE, tick() calls are made to give the RTI processing time to handle incoming RTI events without moving the simulation ahead to the next Modeler event. |
Boolean FALSE |
| HLA Join Attempts | Maximum number of join attempts before termination. | Integer 10 |
| HLA Join Federation After Load | Whether the HLA-PM should join the federation after the network model is fully loaded and set up. | Boolean TRUE |
| HLA RTI Host | DNS name or IP address of the host running Pitch pRTI. (Used only with Pitch RTIs.) | String localhost |
| HLA RTI Port | Port number for Pitch pRTI. (Used only with Pitch RTIs.) | Integer 8989 |
| HLA Standard | Which RTI library should be loaded. Possible values are “DOD 1.3”, “IEEE 1516”, “IEEE 1516-Pitch”, and “IEEE 1516e”. | String DOD 1.3 |
| HLA Time Constrained | Whether the Riverbed federate is abiding by the time-constrained HLA time advance behavior. | Boolean TRUE |
| HLA Time Lookahead | Used for time management. To increase simulation speed, set this attribute to the largest value that is reasonable for the simulation. | Double 1e-9 |
| HLA Time Quantum | Specifies a time quantum between time advance requests. 0.0 means no time quantum is enforced between time advance requests. | Double 0.0 |
| HLA Time Regulating | Whether the Riverbed federate is abiding by the time-regulating HLA time advance behavior. | Boolean TRUE |
| HLA Verbose | Whether the HLA-PM report generates verbose progress messages as opposed to error messages only. The default setting is just error messages. | Boolean FALSE |
| HLA Verbosity Level | How much progress information is printed when HLA Verbose is TRUE. Values are 0 (least), 1, and 2 (most). | Integer 0 |