Setting the Sampling Resolution

This operation sets the sample count for a graph. The sample count determines how many sample elements, or discrete elements, will be used to approximate a continuous function.

In the context of a modulation curve, the sample count is the number of discrete effective signal-to-noise ratio (Eb/No) values for which a bit error rate is assigned. The default sample count is 500. Based on the user’s graphically-defined modulation curve, the Modulation Curve Editor assigns bit error rates to 500 evenly-spaced Eb/No values between the low and high bounds of the horizontal axis, inclusive.

The Set Sampling Resolution operation can be used either before a function has been created graphically or after a function has been created/read in. Once the sampling count is set, the editor redraws the graph at the new resolution.