Ets_Obj_Install_Connect_No_Trx()

Abstract

Connects the given link to the given source and destination without selecting transmitters.

Syntax

Ets_Obj_Install_Connect_No_Trx (src_hndl, dest_hndl, installee_hndl)
Argument Type Description
src_hndl EtsT_Obj_Handle Object handle of source node.
dest_hndl EtsT_Obj_Handle Object handle of destination node.
installee_hndl EtsT_Obj_Handle* Object handle of link being installed.

Return Type

EtsT_Compcode

EtsC_Compcode_Success if able to connect the link. EtsC_Compcode_Failure otherwise.

ets_api_obj.h

Details

This function will take an already created link and connect it to the given source and destination. As a time-saving measure, it will not select the transmitters/receivers at source and destination.

This procedure fails if installee_hndl_ptr* references a path object that requires links between its connected sites.