op_strm_connected()

Abstract

Determines if the specified input or output stream of the surrounding processor is attached to a packet stream object.

Syntax

op_strm_connected (strm_type, strm_index)
Argument Type Description
strm_type int type of the stream-of-interest [This value is a numeric code which indicates the type of the stream-of-interest (see Table 82 “Stream Type Symbolic Constants“ on page 25); acceptable symbolic constants for this argument are OPC_STRM_IN and OPC_STRM_OUT.]
strm_index int numeric index of the input or output stream-of-interest [Stream indices start at 0 and increment by one. There is no upper bound on these indices, but conservation of memory is achieved if they are utilized in a contiguous manner. A value which is negative, or greater than the largest allocated input or output stream index will cause an error.]

Return Type

Boolean

Boolean value indicating whether the specified stream index is occupied by a packet stream. The returned value is OPC_TRUE if the specified stream is connected, OPC_FALSE otherwise.

Example

/** loop through all input streams, generating an access interrupt for each **/

/* determine the number of allocated input streams */
alloc_instrms = op_strm_max_index_in ();

/* loop through each allocated stream */
for (i = 0; i <= alloc_intstrms; i++)
	{
	/* if an input stream is connected, and... */
	if (op_strm_connected (OPC_STRM_IN, i) == OPC_TRUE)
		{
		/* if an input stream is connected, access a packet from the source module. */
		op_strm_access (i);

		/* Collect and forward the packet onto the bus, if one was obtained. */
		if (op_strm_empty (i) == OPC_FALSE)
			op_pk_send (op_pk_get (i), OUTSTRM_BUS);
		}
	}

Details

The input and output streams of modules can be connected together, or left unoccupied. In addition, input and output streams may be sparsely connected. As an example, a processor can have four allocated input streams, with only streams 1 and 3 connected. The status of an input or output stream, in terms of being connected, can be determined using this KP.

Out-of-range or negative stream indices will be interpreted as unoccupied inputs and this KP will accordingly return the constant OPC_FALSE, but no error messages will be generated.

Purpose

Provides a mechanism for a process to distinguish between connected and unconnected streams belonging to the surrounding processor or queue. This is important when a certain operation has to be done for every connected input or output stream. A process can loop through all allocated input or output streams (using the KPs op_strm_max_index_in() and op_strm_max_index_out() to determine the loop bounds), and only perform such an operation on those streams that prove to be connected.

Errors

  • Program Abort: KP requires process context.